801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
P:\INSTALLATION INST\ELECTRIFIED LOCKSET\Z7200\INST-Z7200.vsd REV G 04-13 Page 1
INSTALLATION INSTRUCTIONS
CYLINDRICAL LOCK Z7200
FOR USE ON DOORS 1-3/8” ~ 2" (35mm ~ 51mm) THICK
1. MARK DOOR
2. DRILL HOLES
a. Mark centerline on door face and door edge
(usually 38" from finished floor)
b. Select backset 2-3/8” or 2-3/4” and mark hole
center on door face
NOTE: BACKSET ON DOOR FACE MUST BE
THE SAME AS BACKSET OF YOUR
LOCK.
c. Mark two holes for screw post.
2-1/8” (54mm)
Hole for lockset
5/16” (8mm) hole for
screw post
a
b
c
1" or 31/32"
(24.6mm or 25.4mm)
hole for latch
Fold template for High or
Low Bevel positioning
(reference template)
OPTIONAL:
DOOR CORE DRILLING GUIDE #7000-DG &
CORING DRILL BIT #7000-DB
TOOLS REQUIRED FOR NEW INSTALLATION:
1 philips head screwdriver 1 2-1/8” (54MM) hole saw
1 1" (25.4mm) drill bit 1 5/16” (8mm) drill bit
1 chisel 1 file
LATCH
LOCK BODY
ASSEMBLY
OUTSIDE
MOUNTING
PLATE
OUTSIDE
ROSE
OUTSIDE
LEVER
INSIDE
LEVER
LEVER
CATCH
TOOL
INSIDE
ROSE w/LINER
INSIDE MOUNTING
PLATE
Comments to this Manuals